| AC Changeover Systems and DC Link BoxAC Changeover There are 3 models in the range, which cater for differing power levels and different numbers of Multi's. All of the units share the following features: - A time delay on the switch across to generator power. This allows the generator time to run up to speed and stabilise before being put on load.
- Split output groups - High load and Inverter loads. When on generator or shore-power both groups are connected, when on inverter the High loads are disconnected.
- On board LED's to indicate shore available, Generator starting and Generator in use.
- Connections for Victron MultiPlus duo panel
- Connections to Victron Multi 'virtual switch' and Victron battery monitor to allow these units to inhibit use of High load circuits.
- RJ 45 socket connection for ESP system panel.

|